How to use NO-BLAST
- Shake well before use.
- Remove oil and foreign bodies from the surface as is needed for ordinary painting..
Treat the surface like general painting - Remove heavy and loose rust with wire brush.
Adjust quantity of NO-BLAST depending on the corrosion status. - Secure a dried surface before applying NO-BLAST
If the surface is not even with leftovers after applying NO-BLAST, mildly brush the surface. - Paint 1-2 time(s) using sprayer or brush
- Work should not be performed below 5℃ and over 90% of relative humidity.
- Coating thickness is ranging from 15 to 20㎛.
- Recommended amount to use: 20㎡/ℓ
(The volume may increase/decrease according to the surface environment.) - After using NO-BLAST, dry the surface completely for top coating.
(Dry it for at least 12 hours)
NO-BLAST Storage
※ See Material Safety Data Sheet (MSDS).
The material is prepared with experiments and experience in using NO-BLAST. Thus, its contents may change
- Avoid exposure to the fire, sunlight and keep in dark and dry space. Store in an airtight container at room temperature ( -5c ~ 35c )
- Keep out of reach of children
- Storage term to be 12 months
- Do not store in steel or metal containers.
- Do not use mixed with other products
- Wear gas mask, protective goggle, and protective gloves for safety during work
- Do not use a used container for other purposes.
- Change air frequently when working in a closed area
- For skin contact, flush with water
- Store the rest of NO-BLAST in a tightly sealed plastic container.